We take pride in the manufacture of high-quality spectroscopic instrumentation. From the optical specialists who grind, polish, and coat our mirrors and fabricate our holographic gratings, to the machinists who manufacture our precision scanning drives and the electronic engineers who design the circuits for our CCD detectors and the computer specialists who write the software, the men and women of Laser Spectra Services are committed to providing the best instrumentation possible.
Spectrometers & Monochromators

|
We offer a complete selection of spectrometers to meet the demands of any research, testing or quality-control application. Among the instruments described on this website you will find a match for your requirements in spectral coverage, efficiency, purity and resolution. |
Current Monochromators

Below is given a brief specification on all of our spectrometers and spectrographs. You can access more detailed information on a particular spectrometer/spectrograph by selecting the spectrometer name or model from the first column.
more>>
Spectrometer and Spectrograph Guide
| Model |
Focal Length |
Imaging |
F Nbr |
Wavelength Range |
Resolution |
Dispersion |
H10 |
100mm |
- |
F/3.5 |
185nm-3.2µm |
1nm |
8nm/mm |
CP140 Spectrograph |
140mm |
Yes |
F/2.0 |
190nm-2.5µm |
- |
- |
Micro HR
(manual/ motorized) |
140mm |
Yes |
F/3.88 |
150nm-15µm |
0.3nm |
- |
TRIAX 180/190 |
190mm |
Yes |
F/3.9 |
185nm-40µm |
0.3nm |
3.6nm/mm |
Gemini-180 (double) |
180mm |
- |
F/3.8 |
185nm-40µm |
0.15nm |
1.77nm/mm |
H20 |
200mm |
- |
F/4.2 |
185nm-3.2µm |
0.5nm |
4nm/mm |
CP200 Spectrograph |
200mm |
Yes |
F/2.9 |
190nm-1.3µm |
- |
- |
Triax 320/322 |
320mm |
Yes |
F/4.1 |
185nm-40µm |
0.06nm |
2.64nm/mm |
500M |
500mm |
- |
F/4.0 |
185nm-40µm |
0.02nm |
1.6nm/mm |
Triax 550/522 |
550mm |
Yes |
F/6.4 |
185nm-40µm |
0.025nm |
1.55nm/mm |
750S / 750I |
750mm |
Yes (I) |
F/6.0-F/7.5 |
185nm-40µm |
0.015nm |
1.1nm/mm |
750M |
750mm |
Option |
F/6.0 |
185nm-40µm |
0.01nm |
1.1nm/mm |
1000M |
1000mm |
- |
F/8.0 |
185nm-40µm |
0.008nm |
0.8nm/mm |
U1000 (double) |
1000mm |
- |
F/8.0 |
185nm-40µm |
0.004nm |
0.4nm/mm |
1250M |
1250mm |
- |
F/9.0 |
185nm-40µm |
0.006nm |
0.65nm/mm |
Resolution figures are generally calculated with 6µm slit widths in the visible and 1200g/mm gratings except for the U1000 where resolution is based on 1800g/mm gratings and the THR1500 where resolution is based on 2400g/mm gratings.
As new instruments and improvements are being made continuously, Laser Spectra reserves the right to change any or all of the above specifications without prior notice.
A full range of accessories is available:
|